Rotator Flow Meter (GPE 2001)
ROTATOR FLOW METER
The F2001 Bi-Rotator Flow
Meter is a positive displacement meter utilized in the most demanding applications
requiring accuracy, long life and ruggedness. It owns two precise machined
helical rotators which share the same size. The two rotators rotate together at
the same speed in the measuring chamber and divide the flowing stream into
segments with equal volume which is precisely designed, and the segments will
join back into one stream on the outlet side of the FlowMeter. By counting thesegments through the meter, the flow can be calculated. The rotationstatus is transferred to thetotalizing register or the transmitter for recording and calculation. Volume indication is determined by mechanical output gearing leading to mechanical register and F9005 Signal Generator.High accuracy is attained bytwo unique helical rotators which feature two finely balanced rotaters (Refer to Figure 1). An adjustor, incorporated on the meter, is used to assure maximum accuracy within the meters flow range.
Features:
- Accuracy up to 0.1%,
over 10:1 turn-down ratio - Extremely long service
life and easy maintenance - Self-lubricating, low
pressure drop, and low noise and vibration - Two unique helical
rotators with no touch, but synchronized by timing gears in the measuring
chamber - No oscillating, reciprocating
or sliding parts or cranks to wear or disturb the balanced rotary action
Specification:
- Accuracy: 0.1% ofreading accuracy
- Line size : " to 16"(8 to 400mm)
- Repeatability: 0.02%
- Working Pressure:Customized
- Pulse Output: (18 to
36V, VH=20V,) VL<1V and output load 200 ) - Process temperature: -
22 to 480 F (-30 to 250 ) - Current Output: 4 to
20mA, (two wire system w/ 600 max loop load) - RS485 Output:
communication with Modbus - Viscosity: 0 to 20,000
cP - RTU (powered by 18 to
36V and <60mA) - Protection: IP 65( IP67
for option) - Display: Instantaneous /
Total / Batch flow - Ambient Temperature: -4
to 131 F(-20 to +55 ) - Ambient Humidity: 5% to
95% RH @ 75 F - User Parameters: K
factors, linear correction coefficient flowrate input signal section points,
temperature and - pressure compensation,
set pulse output range, decimal adjustment, etc. - Communication Baud Rate:
Optional (1200 ,2400, 4800 or 9600)
Materials of Construction:
- Housing: Welded Steel
Construction CombiningSteel Castings and DrawnSteel Plate - Rotators: Three/Four
Lobe Rotator - Cast Iron/SS304/ SS316/ SS420 - Measuring Chamber: Cast
Iron/SS304/SS316 - Rotator Shafts: E.T.D.
150 - Rotator Bearings:
Stainless Steel (Standard) , other materials (Optional) - Body and End Covers:
Cast Iron, Cast Steel,SS304, SS316 - Counter Base Plate: Cast
Steel - Body: Cast iron, Cast
steel, SS304,SS316 - O-Ring: Viton (Standard)
- Drive Shafts, Drive
Gears, and Ball Bearings:Stainless Steel