Alat Ukur Kalibrasi
Sensor Type :
C tube (10-40mm) / U tube (50-150mm)
Size :
10mm ~ 200 mm (3/8" ~ 8")
Flow Range :
0 - 1000 Kg/Hr ~ 0 - 1106000 Kg/Hr
Accuracy :
+/-0.2% +/-ZS of reading (Standard)
+/-0.1% +/-ZS of reading (Optional)
Repeatability :
+/-0.03% +/-ZS of reading
Density Range :
200 - 2300 Kg/M3 (0.2 - 2.3 g/cm3)
Accuracy :
+/-0.002 g/cm3
Temperature Range :
-40 °C ~ +125 °C (Standard)
-40 °C ~ +250 °C (Optional, Separate Only)
Material :
Wetted Parts : Stainless Steel 316L
Flange : Stainless Steel 316L
Sensor Housing : Stainless Steel 304
Junction Box : Aluminum Alloy (Epoxy Paint)
Process Connection :
Flange
Flange Type :
JIS 10K / JIS 20K / JIS 40K
ANSI 150# / ANSI 300# / ANSI 600#
DIN PN 10 / PN 16 / PN25 / PN 40
Protection Class :
IP 67
Explosion Proof Exde (ib) IIC T6 (Optional)
Installation :
Compact or Separate
Signal Cable Length :
10M - 100M
Display :
2 lines LCD with illumination
Flow Rate Unit : g/s, Kg/min, kg/Hr, T/Hr, 6 Digit
Density Unit : Kg/m3, g/cm3, 6 Digit
Totalizer Unit : g, Kg, Ton, L, M3, 7 Digits
Temperature : °C, °F, 4 Digits
Keypad :
Infrared light Sensor, can be programmed without Opening the cover
Turndown Ratio :
20 : 1
Damping :
0.01 To 1.0 Seconds
Low Flow Cut off :
0.0% ~ 9.0%
Communication :
RS485 (Modbus Protocol) (Standard)
Hart Signal (Optional)
Current Output :
4-20 mA (Isolated)
Load : Max. 750 W
Output Unit : Mass / Volume / Density / Temperature
Pulse (Alarm) Output :
Open Collector
Rating : 3-30Vdc, 50mA Max.
Power Supply :
90-260 VAC, 50/60 Hz or 24 VDC +/-10%
Power Consumption :
30 - 40 W (Depend on sensor size)
Cable Entry :
Sensor to Converter- 3/4" G
Signal output / Power supply- M20
Ambient Temperature :
-40 °C to +60 °C
Max. Pressure :
63 Kg/cm2